Electrical ratings – System Sensor DH400ACDCP User Manual

Page 12

background image

D400-13-00

12

I56-0555-010R

Electrical Ratings

Power Supply Voltage

20 - 29 VDC

24 VAC 50 - 60 Hz

120 VAC 50 - 60 Hz

220/240 VAC 50 - 60 Hz

CURRENT REQUIREMENTS (USING NO ACCESSORIES)

Max. standby current

25 mA

35 mA AC avg.

20 mA AC avg.

20 mA AC avg.

Max. alarm current

95 mA

55 mA AC avg.

55 mA AC avg.

30 mA AC avg.

CONTACT RATINGS

Alarm initiation contacts (SPST)

2.0A @ 30 VAC/DC (0.6 power factor)

Alarm auxiliary contacts (DPDT)

10A @ 30 VDC

10A @ 250 VAC

Trouble contacts (SPST)

0.3A @ 32 VDC (resistive)

Note: Alarm auxiliary contacts must switch 500 mA minimum at 24VDC. Alarm auxiliary contacts shall not be

connected to inititaing circuits of control panels. Use the alarm initiation contact for this purpose.

ACCESSORY CURRENT LOADS AT 24 VDC
DEVICE
APA451
PA400
RA400Z
RTS451/ RTS451KEY

STANDBY
12mA MAX
0mA
0mA
0mA*

ALARM
30mA MAX
15mA MAX
10mA MAX
10mA MAX*

ANY COMBINATION OF ACCESSORIES MAY BE

USED SUCH THAT THE GIVEN CURRENT LOADS TOTAL:

100mA OR LESS IN THE STANDBY STATE,

150mA OR LESS IN THE ALARM STATE.

*NOTE: WHEN INITIATING AN ALARM, THE RTS451/

RTS451KEY REQUIRES 95 mA MAXIMUM IN

PRE-ALARM AND 103 mA MAXIMUM IN ALARM.

NOMINAL STANDBY CURRENT IS 0mA. ALARM

CURRENT IS 10 mA MAXIMUM WHEN TEST

MAGNET IS REMOVED.

Three-Year Limited Warranty

System Sensor warrants its enclosed product to be free from defects in

materials and workmanship under normal use and service for a period

of three years from date of manufacture. System Sensor makes no other

express warranty for the enclosed product. No agent, representative,

dealer, or employee of the Company has the authority to increase or alter

the obligations or limitations of this Warranty. The Company’s obliga-

tion of this Warranty shall be limited to the replacement of any part of

the product which is found to be defective in materials or workman-

ship under normal use and service during the three year period com-

mencing with the date of manufacture. After phoning System Sensor’s

toll free number 800-SENSOR2 (736-7672) for a Return Authorization

number, send defective units postage prepaid to: System Sensor, Returns

Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174.

Please include a note describing the malfunction and suspected cause

of failure. The Company shall not be obligated to replace units which

are found to be defective because of damage, unreasonable use, modi-

fications, or alterations occurring after the date of manufacture. In no

case shall the Company be liable for any consequential or incidental

damages for breach of this or any other Warranty, expressed or implied

whatsoever, even if the loss or damage is caused by the Company’s

negligence or fault. Some states do not allow the exclusion or limita-

tion of incidental or consequential damages, so the above limitation or

exclusion may not apply to you. This Warranty gives you specific legal

rights, and you may also have other rights which vary from state to state.

Please refer to insert for the Limitations of Fire Alarm Systems

H0538-00