background image

For Additional Technical Information,

PHONE 800-365-0024

STATE WATER HEATERS

500 Tennessee Waltz Parkway, Ashland City, TN 37015

www.statewaterheaters.com

SCGSS00205

© 2005 State Industries, Inc.

Printed in U.S.A.

March 2007R

For complete information on limited warranties, consult written warranty,
or contact the State Customer Care Center, 1-800-365-0024.

State Industries, Inc. reserves the right to make product changes or improvements without prior notice.

T

ITAN

Low-NOx Commercial Gas Water Heaters

DIMENSIONS AND WEIGHT – ALL MODELS

CAPACITY, INPUT AND OUTPUT

POWERED
BURNER

SUGGESTED SPECIFICATION

Water heater(s) shall be State Model ________________ or equal, with maximum storage capacity of 85
gallons, an input rating of ___________________ BTU/Hr., a recovery rating of ____ GPH at 100ºF temperature
rise, and minimum thermal efficiency of 80%. Heater(s) shall meet ASHRAE/IESNA 90.1-1999 requirements for
thermal efficiency and standby loss, and meet SCAQMD R1146.2 low-NOx requirements. In addition, heater(s)
shall: 1) Include a powered gas burner, redundant main gas valves, gas pressure regulator and flame inspection
port. 2) Include a high-temperature limit control, dual-bulb thermostat for accurate temperature control and anti-
stacking compensation and a factory-installed AGA rated temperature and pressure relief valve. 3) Be equipped
with 1-1/2" NPT water inlet and outlet and a boiler-type handhole cleanout. 4) Shall be constructed and stamped
in accordance with ASME Boiler and Pressure Vessel Code and be so marked for a maximum working pressure of
160 psi. 5) Have a glass-lined steel tank with multiple anodes for corrosion protection, and polyurethane foam
insulation. 6) Tank shall have a 3-year limited warranty against corrosion as outlined in the written warranty.

Venting: GPG heater(s) shall be supplied with a Barometric Draft Regulator for conventional atmospheric venting.
GPV heater(s) shall be supplied with an optional vent kit allowing for horizontal sidewall venting or direct venting.

Burner and Controls: Burner(s) shall be pre-mix design, with internal FGR and thermal cutoff, separate spark pilot
ignition system, integral blocked flue sensor, glass view port, main gas regulator, automatic gas valve, manual test
cock and manual gas shutoff. Burner(s) must be factory-installed, tested and started by an Authorized State Start-
up Agent before being placed into operation.

Based on 80% Thermal Efficiency obtained in State engineering laboratories.
To compensate for effects of high altitude above 2,000 feet, recovery ratings should be reduced 5% for every 1,000 feet above sea level.
Current Draw (120V, 60Hz, 1 Phase): 6.0 Amps

*D dimension is for atmospheric vent size (GPG models).
**E dimension is for direct and sidewall vent size (GPV models).
***Minimum gas supply pipe is 1-1/4". See Reference Manual, Table 7 for gas supply pipe size.

MODEL

NUMBER

GPG85 540 NEA

GPV85 540 NEA

GPG85 650 NEA

GPV85 650 NEA

GPG85 740 NEA

GPV85 740 NEA

FIRST

HOUR

RATING

100° F

RISE

583

2206.7

690

2611.7

778

2944.7

TANK

SIZE

85

321.7

85

321.7

85

321.7

BTU

INPUT

PER

HOUR

540,000

650,000

740,000

Gallons

or

Litres

U.S. Gallons

Litres

U.S. Gallons

Litres

U.S. Gallons

Litres

GPH

or

LPH

GPH

LPH

GPH

LPH

GPH

LPH

40°F

4°C

1309

4954.6

1579

5976.5

1794

6790.3

100°F

56°C

523

1979.6

630

2384.6

718

2717.6

140°F

78°C

374

1415.6

450

1703.3

512

1937.9

RECOVERY-GALLONS

PER HOUR AT °F

TEMPERATURE RISE

Inches

or

CM

Inches

CM

950 Lbs.

431.8 Kg

GAS

CONN.***

1

˝

-

A

80-3/4

205.1

B

73

185.4

C

32-1/4

81.9

D

9

22.9

E

26-1/2

67.3

F

26-1/2

67.3

G

93

236.2

H

29-1/2

74.9

I

48-1/2

123.2

DIMENSIONS

SHIPPING

WEIGHT

Page 2 of 2