1-1. Operating Environment
Operating temperature
+5 dC to +40 dC
Performance temperature
+10 dC to +35 dC
Humidity
10 to 90 % (No condensation)
Mass: PFV-SP3100
Approx. 8.5 kg
(Without the optional unit and
board)
HK-PSU01
Approx. 1 kg
To prevent overheating of PFV-SP3100, ensure that there
is good air circulation around the unit.
w
Do not put the unit in a place subject to excessive lamp
smoke, vapor, moisture, or dust, otherwise a fire or electric
shock may result.
c
Install in a stable location.
Installation on unstable or tilting surface may cause the
unit fall off, resulting in injury.
1-2. Power Supply
1-2-1. Power Supply Specifications
Power voltage
AC 100 V to 240 V
Power frequency
50 Hz or 60 Hz
Current consumption
1.0 to 0.5 A
Rush current
AC 100 V IN : 10 A
AC 240 V IN : 33 A
n
AC power supply is required a capacity which is commen-
surate with rush current.
If the capacity of the AC power supply is not enough, the
breaker of AC power on the supply side may operate or
this unit may not operate normally.
1-2-2. Recommended Power Cord
For customers in the U.S.A. and Canada
Required Part
1 Power cord, 125 V 10 A (2.4 m) : ! 1-557-377-11
For customers in the United Kingdom
Required Part
2 Power cord, 250 V 10 A (2.5 m) : ! 1-782-929-11
n
For the customers outside of the area as shown above,
please contact your local Sony Sales Office/Service Center.
w
. Use a specified power cord only.
Be sure to use a recommended power cord to avoid fire
and/or an electric shock.
. Ground the unit for your safety.
Be sure to attach a ground wire to avoid an electric shock.
AC inlet
1
2
AC inlet