beautypg.com

Instructions for the installer – Smeg CIR597X5 User Manual

Page 7

background image

Instructions for the installer

9

2

Side clearances – (Measurements B & C)

Where B, measured from the periphery of the nearest

burner

to any

vertical

combustible surface

, is less than 200 mm, the surface shall

be protected in accordance with Clause 5.12.1.2 to a height C of not
less than 150 mm above the

hob

for the full dimension (width or

depth) of the cooking surface area. Where the cooking

appliance

is

fitted with a ‘splashback’, protection of the rear wall is not required.

3

Additional requirements for Freestanding and Elevated Cooking
Appliaces – (Measurements D & E)
Where D, the distance from the periphery of the nearest

burner

to a

horizontal

combustible surface

is less than 200 mm, then E shall be

10 mm or more, or the horizontal surface shall be above the

trivet

.

See insets above.

NOTES

1

Requirement 3 does not apply to a freestanding or elevated
cooking appliance which is designed to prevent flames or the
cooking vessels from extending beyond the periphery of the
appliance.

2

The ‘cooking surface area’ is defined as that part of the appliance
where cooking normally takes place and does not include those
parts of the appliance containing control knobs.

3

For definition of hob, see Clause 1.4.64.

4

For definition of trivet, see Clause 1.4.109.

5

Consideration is to be given to window treatments when located
near cooking appliances. See Clause 5.3.4.