beautypg.com

Conversion kit – Smeg PU75 User Manual

Page 4

background image

Conversion Kit

6

4)

To adjust the cooktop for LP gas or to return to Natural Gas use, refer to the tables here below.

PU 64 - Natural gas

PU 64 - LP

Qt

Injector

Qr

Qt

Injector

Qr

Qr

BTU

Ø mm

BTU

BTU

Ø mm

BTU

BTU

Front Right

3800

0.82

1500

Front Right

4000

0.60

1500

0.40

Front Left

5200

0.95

1800

Front Left

5400

0.67

1800

0.40

Rear Right

10000

1.30

4000

Rear Right

10300

0.95

4000

0.58

Rear Left

7200

1.13

3000

Rear Left

7300

0.78

3000

0.50

PU 75 - Natural gas

PU 75 - LP

Qt

Injector

Qr

Qt

Injector

Qr

Qr

BTU

Ø mm

BTU

BTU

Ø mm

BTU

BTU

Front Right

3800

0.82

1500

Front Right

4000

0.60

1500

0.40

Front Left

3800

0.82

1500

Front Left

4000

0.60

1500

0.40

Central

A

12000

1.30

4000

Central

A

11500

0.87

4000

0.58

B

0.71

B

0.48

Rear right

5200

0.95

1800

Rear right

5400

0.67

1800

0.40

Rear left

7200

1.13

3000

Front Left

7300

0.78

3000

0.50

PU 75 - Natural gas

PU 75 - LP

Qt

Injector

Qr

Qt

Injector

Qr

Qr

BTU

Ø mm

BTU

BTU

Ø mm

BTU

BTU

Central

right

A

12000

1.30

4000

Central

right

A

11500

0.87

4000

0.58

B

0.71

B

0.48

Central

left

A

12000

1.30

4000

Central

left

A

11500

0.87

4000

0.58

B

0.71

B

0.48

Front Right

3800

0.82

1500

Front Right

4000

0.60

1500

0.40

Front Left

3800

0.82

1500

Front Left

4000

0.60

1500

0.40

Rear Right

7200

1.13

3000

Rear Right

7300

0.78

3000

0.50

Rear Left

5200

0.95

1800

Rear Left

5400

0.67

1800

0.40

NOTE: For reference parameters A and B on the central left and the
central right burners, see drawings on the right.