Installation instructions – Sharp AN-CM270 User Manual
Page 7
PAGE 7
INSTALLATION INSTRUCTIONS
CEILING BRACKET AN-CM270
IF YOU INTEND TO RUN AUDIO OR VIDEO CABLES THROUGH THE CEILING PLATE
PROCEED WITH STEP 5.1 AND 5.2, OTHERWISE PROCEED TO STEP 5.3:
5.1 Cut opening in the ceiling plate trim cover as indicated on the label inside cover near
the center bushing.
5.2 Thread cables through the plastic trim cover.
DO NOT RUN THE AC POWER CORD INSIDE THE PLASTIC TRIM COVER.
ALL WIRING MUST COMPLY WITH THE NEC AND ALL LOCAL BUILDING,
ELECTRIC, AND SAFETY CODES.
STEP 5 ATTACH THE POSITIONING ASSEMBLY TO THE CEILING PLATE
FIGURE 9
Ceiling Trim Cover
Cable Access Hole
Washer
Locking Hex Nut
Upper Knuckle
Assembly
4.3 Fold the attachment plate do wn on its hinge. See Fig. 8
4.4 Install the M4 knurled thumb screw by hand. See Fig. 8. DO NOT USE TOOLS TO
TIGHTEN THIS SCREW.
M4 Knurled Thumb Screw
REMINDER: MAKE SURE TO ALLOW SUFFICIENT SLACK IN THE WIRING TO PERMIT THE
PROJECTOR TO SWING DOWN ON THE HINGE TO ALLOW EASY SERVICING OF THE FILTER
AND THE LAMP ASSEMBLY.
FIGURE 8