3. some part of air conditioner does not operate – Sanyo STB1220C1 User Manual
Page 35

7-3. Some part of air conditioner does not operate.
7-3-1. Only fan does not run.
7-3-2. Electric heater does not work.
Both for (cooling & electric heating models) and (heat pump model)
• Measure resistance of electric
heater winding.
Blown
• Check continuity for thermal
fuses.
Replace them.
• Measure coil resistance of
heater relay.
• Check PCB Ass'y. (Power pack)
(Only for heat pump model)
• Check to see if the circuit of
heater thermostat is opened or
closed ?
Fan cannot
be turned.
OK
• Check fan rotation.
Turn fan gently once or twice by
hand.
• Check fan casing
foreign matter on
inside.
Fan motor burnout
or foreign matter in
bearings.
Remove foreign
matter or repair.
Repair or replace.
• Measure resistance of fan motor
winding.
• Check fan motor capacitor and
4P-connectors (Socket and Plug).
• Check PCB Ass'y . (Power pack)
(Only for heat pump model)
31