INSTALLATION

20221081 / F

23

RGC12 Gyro Compass

PROCESSING UNIT

HS50

P203

P204

or

P202,

232 OUT

422+ OUT

422- OUT

GND

RGC12

TERMINAL BOARD

GRXH

GRXL

TB7

Simrad RA40/RA50 Radar

PROCESSING UNIT

P208

HS50

AD10_D

AD10_GND

AD10_C

RADAR

GYRCK-

GYRCK+

GYRCK+

GYRCK-

26

27

9

10

Note!

Requires the optional 36-pins connector 72099 for the Radar.

Software set-up in Radar

1

Go to menu:

MENUSETUPCUSTOMPRESET1

2

Change Input from

NMEA

to

10 BIT

3

Change Head from

TRUE

to

MAGNETIC