Installation, Rgc12 gyro compass, Simrad ra40/ra50 radar – Simrad HS50 User Manual
Page 31: 2change input from, 3 change head from

INSTALLATION
20221081 / F
23
RGC12 Gyro Compass
PROCESSING UNIT
HS50
P203
P204
or
P202,
232 OUT
422+ OUT
422- OUT
GND
RGC12
TERMINAL BOARD
GRXH
GRXL
TB7
Simrad RA40/RA50 Radar
PROCESSING UNIT
P208
HS50
AD10_D
AD10_GND
AD10_C
RADAR
GYRCK-
GYRCK+
GYRCK+
GYRCK-
26
27
9
10
Note!
Requires the optional 36-pins connector 72099 for the Radar.
Software set-up in Radar
1
Go to menu:
MENU → SETUP → CUSTOM → PRESET1
2
Change Input from
NMEA
to
10 BIT
3
Change Head from
TRUE
to
MAGNETIC