beautypg.com

SpectraLink Link 150 M3 MCU User Manual

Page 37

background image

SpectraLink Corporation

Installation and Operation

Link WTS – Link 150 M3 MCU

STATUS LEDs

Description

Action

4, 5

The switch type selected is not supported

by this MCU.

Verify that the switch type selected is correct. If the type

is incorrect, repeat the steps to select a new switch type.

See section 6.3

Install MCUs -Set Switch Interface Type

1, 4

The operator is trying to register a

handset or place an admin call on an

MCU with no phone lines.

Return mode switch to the NORMAL position.

2, 4

The MCU was powered on with the mode

switch in the wrong position.

Turn off the MCU, place the mode switch to the

NORMAL position and turn back on.

3, 4

Configurations on a multi-MCU

installation do not match in each of the

units.

Most likely to occur when an MCU was

just added to the system.

Erase the configuration in the MCU with incorrect

configuration definitions (probably the MCU that was

just added.) To erase the configuration, refer to section

9.5

Replace an MCU.

Note:

Do not erase the configurations in all the MCUs. In

multiple MCU installations the handset registration

information is shared among the MCUs. This allows you

to replace an MCU without re-registering all the

handsets.

1, 3, 4

REGISTER or ADMIN mode selected

on more than one MCU at the same time.

Only one mode switch can be in ADMIN or REGISTER

at a time. Check the MCUs and take one of them out of

REGISTER or ADMIN mode.

2, 3, 4

The MCU was powered on with the mode

switch in the wrong position.

Turn off the unit, place the mode switch to the

NORMAL position and turn back on.

1, 2, 3, 4

Internal problem with the MCU.

Contact SpectraLink Customer Service for technical

support.

1, 5

The MCU was powered on with the mode

switch in the wrong position.

A possible Base Station failure has been

detected. A Base Station that had

previously been heard by another Base

Station can no longer be heard.

Turn off the MCU, place the mode switch in the

NORMAL position and turn back on..

Check to see if the system was powered on with the

switch in the wrong position. If not, contact SpectraLink

Customer Service.

5

The MCU was powered on with the mode

switch in the wrong position.

One or more of the Base Stations on this

unit is disabled because it is located too

close to other Base Stations. The

ERROR display refers to the LED that is

red. If more than one LED is red, it refers

to the lowest numbered Base Station.

Turn off the MCU, place the mode switch in the

NORMAL position and turn back on.

Identify which Base Station has been disabled and

move it away from its nearest neighbor Base Station

If Mode switch is in ADMIN mode:

Adjust the companding mode from Mu law to A law.

Refer to section 12.2

Change Companding

3, 5

The MCUs have incompatible versions of

software.

Contact SpectraLink Customer Service for technical

support.

PN: 72-0075-01-F.doc