USE

WARNINGS:

When the plate is switched on for the first time, or if it has remained unused for a long period, it
should be dried for 30 minutes on switch position n° 1. This will eliminate any moisture that may
have been absorbed by the insulating material.

To correctly use the appliance, remember:

- To place a pan on the plate before switching this on.

- To always use pans with flat and very thick bottoms (see fig. 3).

- To never use pans that are smaller than the plate diameters.

- To dry the bottom of the pan before placing it on the plate.

- Correctly preserve the plate after use by treating it with special products, easily available on the

market. This will keep the surface of the plate clean and bright. The operation will also prevent
the formation of rust. Never allow children to play near the appliance when using the plates. Check
that the pan handles are positioned correctly. The user should never leave the appliance
unattended when cooking with easily inflammable oil and fat.

- The plates will remain hot for a long period of time even after use. Never touch them with the hands

or other objects in order to prevent scorching.

- If the appliance has a glass lid, this could shatter when the cooker becomes hot. Always

disconnect all the plates before closing the lid.

- Immediately disconnect the appliance from the electricity main as soon as cracks are noted on

the surfaces of the plates.

FIG. 3

9

SERVICING

Always disconnect the appliance from the
electricity main before proceeding with any
servicing operation.

8) REPLACING THE ELECTRICAL
COMPONENTS

For access to the various parts, remove the hotplate
from the top of the cabinet. Then overturn it, unscrew
screw “Z” and remove under part. (see fig. 9).
After these actions is possible to work on the
plates, commutators, clamps and input cable.
N.B. In case of substitution of the input
cable, the installer must keep the “earth”

conductor longer than “live” ones, and must
r e s p e c t t h e c a u t i o n s i n p a r a g r a p h
“Electrical connection”.
To reassemble the appliance repeat the inverse
process.

9) TECHNICAL CHARACTERISTICS OF
THE ELECTRICAL COMPONENTS

To facilitate the job of the installer we present a
scheme with the characteristics of the components.

POWER OF ELECTRICAL COMPONENTS DENOMINATIONS W

Normal plate Ø 145 mm – 7 positions with the protector

1000

Normal plate Ø 180 mm – 7 positions with the protector

1500

Rapid plate Ø 145 mm – 7 positions

1500

Rapid plate Ø 180 mm – 7 positions

2000

Thermostat plate Ø 145 mm – 12 positions

1500

Thermostat plate Ø 180 mm – 12 positions

2000

Denominations

W

TYPE AND SECTION OF THE POWER CABLES

Rubber

3 X 1.5 mm

2

(*)

5 X 1.5 mm

2

(*)

4 X 1.5 mm

2

(*)

H05 RR-F

Polycroropene

3 X 2.5 mm

2

(*)

H05 RN-F

Single phase

Three phase

Three phase

Cable type

power power power

230 - 240~

400 - 415 V 3N~

400 - 415 V 2N~

(*) keeping in mind the contemporaneousness factor