Samsung ACC2400C User Manual
Page 59
Connect the power cables.
6
Reassemble the centralized controller.
7
Cable Specifications
N
N
N
N
o
o
o
o
tt
tt
e
e
e
e
Size of cables
0.75mm
2
~1.25mm
2
Cable type
Double-insulation,
2G
208-230V~, 60Hz
Power Supply
Connect the O1 and O2 terminals of the centralized controller to the O1 and
O2 terminals on the electrical component box as shown in figure.
5
C
C
C
C
A
A
A
A
U
U
U
U
T
T
T
T
II
II
O
O
O
O
N
N
N
N
◆
Cable Specifications
N
N
N
N
o
o
o
o
tt
tt
e
e
e
e
Size of cables
Max. length of electric wires from the
indoor unit to the centralized controller
0.75mm
2
~1.25mm
2
1000m(1094 yd)
Cable type
Double-insulation,
2G(Shield Cable)
Centralized
Controller
208-230V~, 60Hz
Do NOT keep the centralized controller cables with a 220V cable
because the centralized controller cables have low voltage.
C
C
C
C
A
A
A
A
U
U
U
U
T
T
T
T
II
II
O
O
O
O
N
N
N
N
◆ The optional kits must be installed by an installation specialist.
◆ Before installing the optional kits, ensure that you have turned
off the main power.
◆ All optional kits cables should be installed according to the
national wiring rules and you must install them in the wall not
to be touched by users.
E-
59
ENGLISH