4. Disassembly and Reassembly

4-1 Compressor Replacement Flow Chart

Samsung Electronics

4-1

Locate cause of defect

Release refrigerant

Disconnect electrical wiring

from compressor

Cut refrigerant lines

from compressor

Plug disconnected lines

Replace compressor

Inspect electrical
wiring for defects,
and terminals for
correct and secure
connections

Solder discharge line

Corrective action

Check refrigerant oil level

Add oil as necessary

Solder suction line

Use nitrogen gas

Perform soldering function

Fill system with nitrogen gas

Check for leakage

Recharge system

Recharge system

Evacuate system

Release nitrogen gas?

Problem?

Low oil level?

N

Y

Y

N

N

Y

Leakage?