Schumacher INC-406AC User Manual
Page 14
![background image](/manuals/145700/14/background.png)
•
10
•
PROBLEM
POSSIBLE CAUSE
REASON/SOLUTION
Charger will not turn on
when properly connected.
AC outlet is dead.
Poor electrical connection.
Check for open fuse or
circuit breaker supplying AC
outlet.
Check power cord and
extension cord for loose
fitting plug.
Battery clips do not spark
when touched together.
The charger is equipped
with an auto-start feature.
It will not supply current
to the battery clips until
a battery is properly
connected. Unlike
traditional chargers, the
clips will not spark if
touched together.
No problem, this is a normal
condition.
REPLACEMENT PARTS
17.
Output Cables (INC-406A)
38-99-000679
Output Cables (INC-406AC)
22-99-001838
BEFORE RETURNING FOR REPAIRS
18.
When a charging problem arises, make certain that the battery is capable
18.1
of accepting a normal charge. Use a good battery to double check all
connections, the AC outlet for a full 120-volts, the charger clips for correct
polarity and the quality of the connections from the cables to the clips and from
the clips to the battery system. The clips must be clean.
When a battery is very cold, partially charged or sulfated, it will not draw
18.2
the full rated amperes from the charger. It is both dangerous and damaging
to a battery to force higher amperage into it than it can effectively use in
recharging.
When an UNKNOWN OPERATING PROBLEM arises, please read the
18.3
complete manual and call the customer service number for information that will
usually eliminate the need for return.
If the above solutions do not eliminate the problem or for information about troubleshooting
or replacement parts, call toll-free from anywhere in the U.S.A.
1-800-621-5485
7:00 am to 5:00 pm Central Time Monday thru Friday