beautypg.com

Pecifications, Gfs s, Gas supply requirements and burner information – Southbend GFS35 User Manual

Page 5: Electrical requirement, Clearances

background image

GFS S

ERIES

T

UBE

F

RYERS

S

PECIFICATIONS

O

PERATOR

S

M

ANUAL

1182026

REV

2

P

AGE

5

S

P

E

C

IFIC

ATIO

N

S

Gas Supply Requirements and Burner Information

Supply pressure should be greater than 7" W.C. for natural gas or greater than 11" W.C. for propane. One
3/4" NPT male connector located on back (see illustrations on pages 4 and 7).

Model

Burners

Gas Type

Manifold

Pressure

Number
per Unit

Rate Each

BTUs/Hour

Total Rate

BTUs/Hour

Orifice Size

Natural

4" W.C.

3

35,000

105,000

#36 - 0.1065" dia.

Main

Propane

10" W.C.

3

30,000

90,000

#52 - 0.0635" dia.

Natural

4" W.C.

1

900

900

#77 - 0.0180" dia.

GFS35

Pilot

Propane

10" W.C.

1

900

900

0.0110" dia.

Natural

4" W.C.

4

35,000

140,000

#36 - 0.1065" dia.

Main

Propane

10" W.C.

4

30,000

120,000

#52 - 0.0635" dia.

Natural

4" W.C.

1

900

900

#77 - 0.0180" dia.

GFS45

Pilot

Propane

10" W.C.

1

900

900

0.0110" dia.

Natural

4" W.C.

5

35,000

175,000

#36 - 0.1065" dia.

Main

Propane

10" W.C.

5

30,000

150,000

#52 - 0.0635" dia.

Natural

4" W.C.

1

900

900

#77 - 0.0180" dia.

GFS65

Pilot

Propane

10" W.C.

1

900

900

0.0110" dia.

Electrical Requirement

No external electric power is required.

Clearances

See page 9.