beautypg.com

Troubleshooting, Ervice – Southbend GFS35 User Manual

Page 23

background image

GFS S

ERIES

T

UBE

F

RYERS

S

ERVICE

O

PERATOR

S

M

ANUAL

1182026

REV

2

P

AGE

23

SE
R

V

IC

E

Troubleshooting

Problem

Likely Cause

Burners do not come on

Gas supply to unit off.
Combination gas valve is in “OFF” or “PILOT” position.
Pilot not ignited.
Thermostat not “ON.”

Pilot will not stay ignited

Combination gas valve is in “OFF” position.
Pilot gas not adjusted properly.
Gas supply to unit off.
Bad thermopile.
Dirty thermopile connections at combination gas valve or high limit.
Bad magnet assembly in combination gas valve.
Clogged orifice.
Draft condition.
Air in gas line.
Improper ventilation system.
Oil excessively hot.

Pilot produces carbon deposits

Unit connected to wrong gas supply.
Pressure not adjusted correctly.
Pilot gas not adjusted correctly.

Burners produce carbon deposits

Wrong size orifices.
Connected to wrong gas supply.
Pressure not adjusted correctly.
Flue obstructed.

NOTE: Vibrations or shock caused by shaking or pounding baskets on top surface or by slamming door may
cause Hi-Limit Control Switch to open. If this condition persists, additional cushioning may be added to the
rubber grommets supporting this control to absorb these shocks.