NOTICE
Warranty will be void and the manufacturer is relieved of all liability if:
(A) Service work is performed by other than a qualified technician,
OR
(B) Other than genuine Southbend replacement parts are installed.
!
WARNING
Adjustments and service work may be performed only by a qualified technician who is experienced in,
and knowledgeable with, the operation of commercial gas cooking equipment. However, to assure
your confidence, contact your Southbend Service Representative (or the Southbend Service
Department) for reliable service, dependable advice or other assistance, and for genuine factory
parts.
!
WARNING
Appliances equipped with casters have been installed with a restraint to limit their movement to
prevent damage to the gas supply connecting system. If disconnection of this restraint is necessary to
move the appliance for cleaning, etc., reconnect it when the appliance is moved to its original
installed position.
Adjustments
All units are adjusted at the factory. In case of problems in operation at initial installation, check type of gas
and manifold pressure and compare with information listed on the serial plate.
Checking and Adjusting Main Burners
The main burners should burn with a steady blue
flame, and the inner cone of the flame from each port
should be about 3/4" long. The flame from each main
burner should enter each heat tube without touching
the front of the frypot or the sides, top, or bottom of
each tube.
Normal Flame
Blowing or Lifting Flames
(too much air)
Yellow Tips
(too little air or too much gas)
3/4"