14

6 FINAL OPERATIONS

Having carried out the above adjustments, reassemble the appliance

following, backwards, the instructions in paragraph “5.1 Removing the
separable control panel

/ 5.2 Removing the hob”.

6.1

Regulation of minimum for natural gas

Reposition the components on the burner and

slide the knobs onto the cock stems.
Light the burner and set it on the minimum
position. Take the knob off again and turn the
regulating screw on the side of the cock stem
until a steady minimum flame is achieved.
Refit the knob and verify the burner flame is
stable (turning the knob rapidly from the
maximum to the minimum position the flame
must not go out).

6.2

Regulation of minimum for LPG

To regulate the minimum for LPG, completely tighten (clockwise) the

screw inside or next to the gas tap pin (depending on the model).
The diameters of the by-passes for each burner are given in table “5.3

Regulation for LPG”.


After having regulated the device with gas other than the one tested,

replace the label located on the guard with the one that corresponds to
the new gas. The label is inside the bag that contains the nozzles

provided.