beautypg.com

4 adjusting for natural gas, Adjusting the primary air flow, 6 reassembling the hob skin – Smeg GKL64-3 User Manual

Page 10: Adjusting for natural gas, Reassembling the hob skin, Instructions for the installer, 5 adjusting the primary air flow

background image

Instructions for the Installer

28

5.4

Adjusting for natural gas

The appliance is tested with G20 (2H) natural gas at the pressure of 20 mbar. To return the
appliance to the condition required to use this type of gas, proceed as described in point “5.2
Adjusting for bottled gas” but select the nozzles and adjust the primary air flow for natural gas,
as indicated in the table below and in point “5.5 Adjusting the primary air flow”.


Burner

Nominal

heat

capacity

(kW)

Natural gas – G20 20 mbar

Nozzle diameter

1/100 mm

Reduced heat capacity

(W)

Auxiliary

1.05

132

400

Semi rapid

1.7

165

500

Rapid (3)

3.5

250

900

Rapid (7)

2.9

230

1.05

Rapid (6)

3.1

240

900

Ultra-Rapid

4.2

300

1100

Internal

0.9

126

400

Double
Crown (4)

External

3.3

250

1200

Internal

0.9

126

400

Double
Crown (8)

External

4.0

140

1200

5.5

Adjusting the primary air flow

Refers to the gap “X” in mm.


BURNER

G20

20 mbar

G30/G31

30/37 mbar

G110

8 mbar

Auxiliary

2.0

10.0

1.0

Semi rapid

2.0

10.0

1.5

Rapid (3)

2.5

8.0

2.0

Rapid (7)

2.5

8.0

1.5

Rapid (6)

2.5

10.0

1.0

Ultra-Rapido

2.5

12.0

5.0

Internal

5.0

5.0

1.0

Double
Crown (4)

External

10.0

10.0

2.5

Internal

5.0

5.0

1.0

Double
Crown (8)

External

13.0

13.0

3.5

To identify the burners on your hob, refer to the drawings in point “5.8 Hob burner
layout”

5.6

Reassembling the hob skin

Reverse the procedure described in point “5.1 Removing the hob skin ”.

When replacing the burner rings, bear in mind that they must be

fully tightened using

the spanner provided.

Put the pan stands back in place, fitting first those at the side and then the central one.








This manual is related to the following products: