52

Technical data

Hicom cordless EM

Mobile telephone

Accessories

Charging shell

For charging the mobile telephone batteries and storing the mobile
telephone safely.

Standards

DECT in accordance with ETSI, CTR 6, CTR
10, GAP

Number of channels

120 duplex channels

Radio frequency range 1.88 GHz to 1.90 GHz

Duplex operation

Time duplex with a 10 ms frame length each

Channel configuration 1728 kHz

Bit rate

1152 kbit/s

Modulation

GFSK

Voice encoding

32 kbit/s (ADPCM)

Transmit power

10 mW average power per channel,
250 mW peak power per channel

Range

Outdoors approx. 300 m,
indoors approx. 50 m

Operating times with
fully charged battery

see page 10

Permitted environ-
mental conditions for
operation

+5 °C to +45 °C
20% to 75% relative humidity

Weight incl. battery

approx. 185 g

Dimensions
(L x W x H)

approx. 155 x 53.6 x 36.2 mm