Instructions for the installer

25

16.

FINAL OPERATIONS

After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids.

Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the
appliance with the one corresponding to the new gas. This label is in the packet together with the
nozzles.

16.1

Regulation of the hob burner minimum level for natural gas

Light the burner and turn it to the minimum position . Extract the gas
tap knob and turn the adjustment screw at the side of the tap rod until
the correct minimum flame is achieved.
Replace the knob and check burner flame stability: (rapidly turning the
knob from maximum to minimum position, the flame should not go
out). Repeat the operation on all the gas taps.

16.2

Regulation of the hob burner minimum level for LPG

In order to adjust the minimum with LPG, the screw at the side of the tap rod must be turned clockwise
all the way.
The bypass diameters for each individual burner are shown in paragraph “15.2 Burner and nozzle
characteristics table". Once the regulation has been completed, restore the seal on the by-passes
using paint or similar materials.

16.3

Mounting the rear top skirtboard

• Loosen nuts B.
• Position the skirt above the top, taking care to

align pins C with holes D.

• Secure the skirt to the top by tightening screws

A.

ALWAYS INSTALL THE REAR TOP

SKIRTBOARD WHICH IS AN INTEGRAL
PART OF THE APPLIANCE

16.4

Wall fixing

• Stretch out the chain attached to the cooker

horizontally so that the other end touches the
wall.

• Mark the wall in the position where the hole is to

be drilled.

• Drill the hole, insert a wall plug and attach the

chain.

• Move the cooker up against the wall.