beautypg.com

Schumacher 94085894 User Manual

Page 9

background image

5

Do not face the battery when making the final connection.

7.5

When disconnecting the charger, always do so in the reverse order of the

7.6

connecting procedure and break the first connection while as far away

from the battery as practical.
A marine (boat) battery must be removed and charged on shore. To

7.7

charge it onboard requires equipment specially designed for marine use.

BATTERy CHARGING - AC CONNECTIONS

8.

This battery charge is for use on nominal 120 volt circuits and requires a

8.1

dedicated 20A circuit.
DANGER – Never alter AC cord or plug provided – if it does not fit the

outlet, have proper outlet installed by a qualified electrician. Improper

connection can result in a risk of an electric shock or fire.
Recommended minimum AWG size for extension cords for battery

8.2

chargers

25

50

100

150

(7.6)

(15.2)

(30.5)

(45.6)

0

2

18

18

18

16

2

3

18

18

16

14

3

4

18

18

16

14

4

5

18

18

14

12

5

6

18

16

14

12

6

8

18

16

12

10

8

10

18

14

12

10

10

12

16

14

10

8

12

14

16

12

10

8

14

16

16

12

10

8

16

18

14

12

8

8

18

20

14

12

8

6

a

If the input rating of a charger is given in watts rather than in

amperes, the corresponding ampere rating is to be determined

by dividing the wattage rating by the voltage rating ± for

example:

1250 watts/125 volts = 10 amperes

Length of cord, feet (m)

AWG size of cord

AC input rating,

amperes

a

But less

than

At least

Grounding Methods

8.3

This charger must be properly grounded. Make sure the AC outlet you are

plugging it into is properly grounded per local codes and regulations. If it

is not, have one installed by a qualified service person. Do not remove or

bypass the grounding pin on the plug or receptacle.

This manual is related to the following products: