beautypg.com

Schumacher 94085894 User Manual

Page 11

background image

7

AGM

– Set button to STANDARD. The Absorbed Glass Matt construc-

tion allows the electrolyte to be suspended in close proximity with the

plate’s active material. In theory, this enhances both the discharge and

recharge efficiency. Actually, the AGM batteries are a variant of Sealed

VRLA (valve regulated lead acid) batteries. Popular uses include high

performance engine starting, power sports, deep cycle, solar and storage

battery. AGM batteries are typically good deep cycle batteries and they

deliver best life performance if recharged before the battery drops below

a 50 percent charge. If these AGM batteries are completely discharged,

the cycle life will be around 300 cycles. This is true of most AGM batteries

rated as deep cycle batteries.
GEL

– Set button to GEL CELL. The Gel Cell is similar to the AGM style

because the electrolyte is suspended, but different because technically

the AGM battery is still considered to be a wet cell. The electrolyte in a

GEL cell has a silica additive that causes it to set up or stiffen. The re-

charge voltages on this type of cell are lower than the other styles of lead

acid battery. This is probably the most sensitive cell in terms of adverse

reactions to over-voltage charging. Gel Batteries are best used in VERY

DEEP cycle application and may last a bit longer in hot weather applica-

tions. If the incorrect battery charger is used on a Gel Cell battery, poor

performance and premature failure is certain.

Gel Cell and some AGM batteries may require a special charging rate.
Batteries should be marked with their type. If charging a battery that is not

marked, check the manual of the item that uses the battery.

OPERATING INSTRUCTIONS

11.

OVERVIEW

11.1

To use this battery charger, first, select an unused outlet from the eight

available and connect the battery and AC power, if necessary, following

the precautions listed under sections 6 and 7. Then, select the appropriate

BATTERY TYPE for your battery and press START. This section explains

a few details.
CHARGING:

11.2

The CONNECTED (red) LED will not light continuously until

a battery is detected. If the charger does not detect a properly connected

battery, the CONNECTED LED will not light. Charging will not begin until

the CONNECTED LED comes on. When charging begins, the CHARGING

(yellow) LED will be lit.
AUTOMATIC CHARGE:

11.3

Once the battery type is selected, press the

START button and the charger automatically selects the charge rate

based on battery size and voltage. When an automatic charge is com-

plete, the charger will switch to Maintain Mode and the CHARGED (green)

LED will be lit.

This manual is related to the following products: