beautypg.com

2 burner and nozzle characteristics table, Instructions for the installer – Smeg HB96CSS-3 User Manual

Page 18

background image

39

Instructions for the installer

9.2

Burner and nozzle characteristics table

Rapid

R

ATED

HEATING

CAPACITY

(

K

W)

LPG – G30/G31 28/37 mbar

Nozzle

diameter

1/100 mm

By-pass

1/100 mm

Reduced

capacity

(W)

Capacity

g/h G30

Capacity

g/h G31

Auxiliary (1)

1.05

50

30

400

76

75

Semi-rapid (2)

1.8

65

33

500

131

129

Rapid (3)

3

85

45

800

218

214

Ultra-rapid (4)

3.9

100

65

1600

284

279

Burner

R

ATED

HEATING

CAPACITY

(

K

W)

NATURAL GAS – G20 20 mbar

Nozzle diameter

1/100 mm

Reduced capacity

(W)

Auxiliary (1)

1.05

72

400

Semi-rapid (2)

1.8

97

500

Rapid (3)

3

115

800

Ultra-rapid (4)

3.9

135

1600

To identify the burners on your hob, refer to the drawings in point “4.
KNOW YOUR APPLIANCE“.

This manual is related to the following products: