BJ5-620 Maintenance 37

of

73

Lubrication Intervals

Shift Operation

Replace Lubricant

Check

One shift operation

Every 18 months

Monthly

Two shift operation

Every 9 months

Monthly

Three shift operation

Every 6 months

Monthly

Check lubricant quality

You can judge whether the lubricant needs to be replaced by checking for the following
features:

• Change in consistency
• Discoloration
• Degree of soiling

Replacing or Refilling Lubricant

• Fill the bearings uniformly with grease until all operating surfaces are well greased.
• For the rotor bearings, a lubricant quantity of one third to a maximum of half of the

bearing volume per bearing is required. If too much grease is used, the lubricant will
become unusable due to excessive temperature.

• Only one type of grease may be used, mixing different types of grease is prohibited.

The bearings have been filled at the factory with lithium base saponification roller
bearing grease F3.

• Refer to the “List of Lubricants” in this section for recommended bearing grease.