Error messages, continued, Error identification and description, continued, Error code – Schneider Electric Lexium 17S Series User Manual
Page 90: Error (fault), Possible cause/corrective action, Motor overtemperature, Irms or ipeak set too high, Defective motor, Reduce motion profile duty cycle, Improve ventilation of the motor

78
Error Messages, continued
Error
Identification
and Description,
continued
Continued on next page
Error
Code
Error (Fault)
Possible Cause/Corrective Action
F06
Motor overtemperature.
- I
rms
or I
peak
set too high.
- Defective motor
- If motor is not hot, check feedback cables and
connectors.
- Reduce motion profile duty cycle
- Improve ventilation of the motor
F07
Internal 24 Vdc fault.
Return drive to manufacturer
F08
Motor speed limit
exceeded.
- Feedback parameters not set correctly.
- Incorrect feedback wiring.
- Motor phases reversed.
- Check Parameter “Overspeed” for correct setting.
F09
EEPROM checksum error. Return drive to manufacturer.
F10
Flash-EPROM checksum
error.
Return drive to manufacturer.
F11
Motor brake fault.
- Brake parameter set to “WITH” when brake does not
exist.
- Defective brake.
- Check motor power cable and connections.
F12
Motor phase missing.
- Defective motor.
- Check motor power cable and connections
F13
Drive internal temperature
exceeded.
- Improve ventilation.
- Reduce motion profile duty cycle.