Specifications 10 – Schumacher Power Inverter PID-410 User Manual
Page 15
![background image](/manuals/142803/15/background.png)
• 15 •
PROBLEM
REASON
SOLUTION
Inverter does not turn on.
Poor contact at terminals
Fuse is blown.
Inverter may be defective.
Check for poor connection
to battery or power supply.
Make sure connection points
are clean. Rock clamps
back and forth for a better
connection.
A blown fuse is usually
caused by reverse polarity
or a short circuit within the
inverter.
To replace, contact a qualified
service technician who will
diagnose the inverter and
replace the fuse(s) with the
appropriate replacement(s).
See warranty and call
Customer Service 1-800-621-
5485 (Hours 7:00 am to 5:00
pm CST).
SPECIFICATIONS
10.
Model: PID-410 / PIF-410
Maximum Continuous Power
410 Watts
Surge Capability (Peak Power)
820 Watts
No Load Current Draw
<0.4A
Wave Form
Modified Sine Wave
Input Voltage Range
10.5V – 15.5V DC
Output Voltage Range
120V ± 5% AC
Low Battery Alarm
Audible, 11V ± 0.3V DC
Low Battery Shutdown
10.5V ± 0.3V DC
High Battery Shutdown
15.0V ± 0.5V DC
Optimum Efficiency
85%
AC Outlet
Two, NEMA 5 - 15 USA
DC Output
One, USB 5V 0.5 Amp
Dimensions
5” L x 4” W x 2.2” H
Weight
approximately 2 lbs.