beautypg.com

Schumacher 00-99-000906 User Manual

Page 19

background image

16

TROUBLESHOOTING

14.

Before Returning For Repairs

When a charging problem arises, make certain that the battery is capable

14.1

of accepting a normal charge. Use a good battery to double check all

connections, AC outlet for a full 120-volts, charger clips for correct polarity

and the quality of the connections from the cables to the clips and from the

clips to the battery system. The clips must be clean.
When a battery is very cold, partially charged or sulfated, it will not draw

14.2

the full rated amperes from the charger. It is both dangerous and damag-

ing to a battery to force higher amperage into it than it can effectively use

in recharging.
When an UNKNOWN OPERATING PROBLEM arises, please read the

14.3

complete manual and call the customer service number for information

that will usually eliminate the need for return.

If the above solutions do not eliminate the problem or for information about

troubleshooting or replacement parts, call toll-free from anywhere in the U.S.A.

1-800-621-5485

PROBLEM

POSSIBLE CAUSE

REASON/SOLUTION

Charger has shut down or

will not turn on when prop-

erly connected.

The charger has gotten too

hot and it has shut down.

The charger has thermal

protection, and it will shut

down if it gets too hot.

Unplug the AC cord and

let the charger cool down.

Make sure there is nothing

obstructing the air flow to the

fans, clean them as shown in

MAINTENANCE INSTRUC-

TIONS.

The cooling fan is making a

rattling noise.

The fan has a buildup of dirt

and grime causing it to be

unbalanced.

Blow the dirt and grime

off the fan blades using

compressed air as described

in the MAINTENANCE

INSTRUCTIONS