5-15. ERROR RATE CHECK

5-15-1. CD Error Rate Check

Checking Procedure:
1. Load the check disc (MD) TDYS-1.
2. Click the

[JOG UP]

or

[JOG DOWN]

to display “CPLAY2

MODE” (C36).

3. Click the

[ENTER/YES]

twice and display “CPLAY2MID”.

4. The display changes to “C =

AD =

”.

5. Check that the C1 error rate is below 20.
6. Click the

[MENU/NO]

to stop playback, then click the

[EJECT]

and take out the check disc.

5-15-2. MO Error Rate Check

Checking Procedure:
1. Load the continuously-recorded disc. (Refer to “5-6. USING

THE CONTINUOUSLY RECORDED DISC”)

2. Click the

[JOG UP]

or

[JOG DOWN]

to display “CPLAY2

MODE” (C36).

3. Click the

[ENTER/YES]

to display “CPLAY2MID”.

4. The display changes to “C =

AD =

”.

5. If the C1 error rate is below 20, check that ADER is 00.
6. Click the

[MENU/NO]

to stop playback, then click the

[EJECT]

and take out the test disc.

5-16. FOCUS BIAS CHECK

Change the focus bias and check the focus tolerance amount.

Checking Procedure:
1. Load the continuously-recorded disc. (Refer to “5-6. USING

THE CONTINUOUSLY RECORDED DISC”)

2. Click the

[JOG UP]

or

[JOG DOWN]

to display “CPLAY2

MODE” (C36).

3. Click the

[ENTER/YES]

twice to display “CPLAY2MID”.

4. Click the

[MENU/NO]

when “C =

AD =

” is displayed.

5. Click the

[JOG UP]

or

[JOG DOWN]

to display “FBIAS

CHECK” (C16).

6. Click the

[ENTER/YES]

to display “

/

c =

”.

The first four digits indicate the C1 error rate, the two digits
after “/ ” indicate ADER, and the 2 digits after “c =” indicate
the focus bias value.
Check that the C1 error is below 20 and ADER is below 2.

7. Click the

[ENTER/YES]

and display “

/

b =

”.

Check that the C1 error is about 100 and ADER is below 2.

8. Click the

[ENTER/YES]

and display “

/

a =

”.

Check that the C1 error is about 100 and ADER is below 2

9. Click the

[MENU/NO]

, then click the

[EJECT]

and take out

the disc.

Note:

If the C1 error and ADER are above other than the specified
value at points a (step 8. in the above) or b (step 7. in the above),
the focus bias adjustment may not have been carried out prop-
erly. Adjust perform the beginning again.

5-17. AUTO GAIN CONTROL OUTPUT LEVEL

ADJUSTMENT

Be sure to perform this adjustment when the optical pick-up is
replaced.
If the adjustment results becomes “Adjust NG!”, the optical pick-
up may be faulty or the servo system circuits may be abnormal.

5-17-1. CD Auto Gain Control Output Level Adjustment

Adjusting Procedure:
1. Load the check disc (MD) TDYS-1.
2. Click the

[JOG UP]

or

[JOG DOWN]

to display “AG Set (CD)”

(C11).

3. When the

[ENTER/YES]

is clicked, the adjustment will be

performed automatically.
“Complete!!” will then be displayed momentarily when the
value is recorded in the non-volatile memory, after which the
display changes to “AG Set (CD)” (C11).

4. Click the

[EJECT]

and take out the check disc.

5-17-2. MO Auto Gain Control Output Level Adjustment

Adjusting Procedure:
1. Load the test disc (MDW-74/GA-1).
2. Click the

[JOG UP]

or

[JOG DOWN]

to display “AG Set

(MO)” (C10).

3. When the

[ENTER/YES]

is clicked, the adjustment will be

performed automatically.
“Complete!!” will then be displayed momentarily when the
value is recorded in the non-volatile memory, after which the
display changes to “AG Set (MO)” (C10).

4. Click the

[EJECT]

and take out the test disc.