beautypg.com

Mds-nt1 – Sony MDS-NT1 User Manual

Page 30

background image

30

MDS-NT1

9. Click the

[ENTER/YES]

to display “EFB =

MO-P”.

Then, the optical pick-up moves to the pit area automatically
and servo is imposed.

10. Observe the waveform of the oscilloscope, and check that the

specified value is satisfied. Do not click the

[JOG UP]

or

[JOG DOWN]

.

Traverse Waveform

11. Click the

[ENTER/YES]

to display “EF MO CHECK (C14)”.

The disc stops rotating automatically.

12. Click the

[EJECT]

button and take out the disc.

13. Load the check disc (MD) TDYS-1.
14. Click the

[JOG UP]

or

[JOG DOWN]

and display “EF CD

CHECK” (C15).

15. Click the

[ENTER/YES]

to display “EFB =

CD”. Servo is

imposed automatically.

16. Observe the waveform of the oscilloscope, and check that the

specified value is satisfied. Do not click the

[JOG UP]

or

[JOG DOWN]

.

Traverse Waveform

17. Click the

[ENTER/YES]

to display “EF CD CHECK” (C15).

18. Click the

[EJECT]

and take out the check disc (MD) TDYS-1.

Check Location: BD board (see page 35)

5-7-7. Focus Bias Check

Change the focus bias and check the focus tolerance amount.
Checking Procedure:
1. Load the test disk (MDW-74/GA-1).
2. Click the

[JOG UP]

or

[JOG DOWN]

to display “CPLAY2

MODE” (C36).

3. Click the

[ENTER/YES]

to display “CPLAY2MID”.

4. Click the

[MENU/NO]

when “C =

AD =

” is displayed.

5. Click the

[JOG UP]

or

[JOG DOWN]

to display “FBIAS

CHECK” (C16).

6. Click the

[ENTER/YES]

to display “

/

c =

”.

The first four digits indicate the C1 error rate, the two digits
after [/] indicate ADER, and the 2 digits after [c =] indicate
the focus bias value.
Check that the C1 error is below 20 and ADER is below 2.

7. Click the

[ENTER/YES]

to display “

/

b =

”.

Check that the C1 error is about 100 and ADER is below 2.

8. Click the

[ENTER/YES]

to display “

/

a =

”.

Check that the C1 error is about 100 and ADER is below 2.

9. Click the

[MENU/NO]

, then click the

[EJECT]

and take out the

test disc.

5-7-8. C PLAY Check

MO Error Rate Check

Checking Procedure:
1. Load the test disk (MDW-74/GA-1).
2. Click the

[JOG UP]

or

[JOG DOWN]

to display “CPLAY2

MODE” (C36).

3. Click the

[ENTER/YES]

to display “CPLAY2MID”.

4. The display changes to “C =

AD =

”.

5. If the C1 error rate is below 20, check that ADER is 00.
6. Click the

[MENU/NO]

to stop playback, then Click the

[EJECT]

and take out the test disc.

CD Error Rate Check

Checking Procedure:
1. Load the check disc (MD) TDYS-1.
2. Click the

[JOG UP]

or

[JOG DOWN]

to display “CPLAY2

MODE” (C36).

3. Click the

[ENTER/YES]

to display “CPLAY2MID”.

4. The display changes to “C =

AD =

”.

5. Check that the C1 error rate is below 20.
6. Click the

[MENU/NO]

to stop playback, then click the

[EJECT]

and take out the check disc.

5-7-9. Self-Recording/playback Check

Prepare a continuous recording disc using the unit to be repaired
and check the error rate.

Checking Procedure:
1. Load a recordable disc (blank disc).
2. Click the

[JOG UP]

or

[JOG DOWN]

to display

“CREC 2MODE” (C37).

3. Click the

[ENTER/YES]

to display “CREC 2MID”.

4. When recording starts and display “CREC 2 @@@@” (@@@@

is the address).

5. About 1 minute later, click the

[MENU/NO]

to stop continu-

ous recording.

6. Click the

[JOG UP]

or

[JOG DOWN]

to display “CPLAY2

MODE” (C36).

7. Click the

[ENTER/YES]

to display “CPLAY2MID”.

8. “C =

AD =

” will be displayed.

9. Check that the C1 error becomes below 20 and the AD error

below 2.

10. Click the

[MENU/NO]

to stop playback, then click the

[EJECT]

and take out the disc.

A

B

VC

Specified value : Below 10% offset value

Offset value (%) = X 100

I

A – B I

2 (A + B)

A

B

VC

Specified value : Below 10% offset value

Offset value (%) = X 100

I

A – B I

2 (A + B)