ROUBLESHOOTING
SEZ S
ERIES
C
OUNTERTOP
S
TEAMERS
P
AGE
18
O
PERATOR
’
S
M
ANUAL
1181587
TROU
BLE
S
H
OOTI
N
G
T
ROUBLESHOOTING
This section contains a troubleshooting key and referenced flowcharts to assist a qualified service technician
in the servicing of an SEZ Series Countertop Steamer. Please note that the unit has a “SERVICE
REQUEST” light that illuminates in the event of certain water supply problems. Also note that when
the unit is turned on, there is an eight-minute time delay before the heating elements come on to
allow time for filling. Therefore, some procedures call for a waiting period when reconnecting power
to the unit or turning the unit on.
TROUBLESHOOTING KEY
Find the symptom below that corresponds to the malfunction, then turn to the corresponding figure and page.
Follow the flowchart on that page until the problem is solved.
Symptom
Page
Unit Not Heating Up, “ON” Light Not Lit
Unit Not Heating Up Properly or Not Cooking Properly, “ON” Light Lit
Excessive Steam Coming from Pressure Relief Vent
“Service Request” Light Comes On During Operation
Buzzer Does Not Come On
TROUBLESHOOTING FIGURES AND PROCEDURES
Figure and/or Procedure
Page
Voltage Check at Control Panel Fuse Block
Heating Element Resistance Check (at Contactor)
Main Fuse Replacement
Power Switch Continuity Check
Contactor and MOV Check
Timer and Buzzer Check
Door Switch Continuity Check
Float Switch Continuity Check
Controller Check
Inlet Float Valve Check
Pressure Switch Check
High-Limit Thermostats Check
Electric Schematic for 208-240 Volt 60 Hz or 220 Volt 50 Hz Model SEZ-3
Electric Schematic for 480 Volt Model SEZ-3
Electric Schematic for 208-240 Volt 60 Hz or 220 Volt 50 Hz Model SEZ-5
Electric Schematic for 480 Volt Model SEZ-5