beautypg.com

Analog input setup – Sierra Wireless MP 880W User Manual

Page 68

background image

MP880W Modem User Guide

62

2130795

Analog input setup

The Analog Input window (

Tools > Options > MP > Input/Output

is used to configure devices on the four analog inputs. Each tab 
corresponds to a pin:

To configure an analog sensor or gauge, select the tab that 
corresponds to the pin you are using and complete the fields as 
follows:

Label: Enter a description of the sensor or gauge (

Measured

Voltage

Vehicle Speed

, etc.), up to 20 characters long.

Raw value: Shows the analog value from the input (read‐
only). The analog input has a 10‐bit (1024‐step) resolution, 
so the raw value range is between 0 and 1023.

Zero scale: Enter the minimum value for the units you are 
reporting (used to convert the raw analog value of zero).

Full scale: Enter the maximum value for the units you are 
reporting (used to convert the raw value of 1023).

Current value: Shows the resulting converted value using 
the zero and full scales entered.

Unit: Specify the units of the input (

volts

km/h

, etc.), up to 

20 characters long.

Example

If you are measuring temperature, and the thermometer you 
have connected to the I/O connector measures between ‐30 
(raw value 0) and +50 (raw value 1023) degrees Celsius, then 
your zero scale is 

-30.0

 and your full scale is 

50.0

. Your label 

could be 

“Temperature

”, and units, 

“degrees C”

.

The measurements are calculated for the 81‐degree range 
(between ‐30 and +50), which is divided into 1024 steps 
(0.0791 degrees per unit step). A reading of 25 degrees 
(56 degrees above the minimum) would therefore show a raw 
value of 708 (56 degrees/0.0791 degrees per unit).

Analog Tab

Connector Pin

Input 1

14

Input 2

7

Input 3

15

Input 4

8