beautypg.com

3 regulation for natural gas, 4 regulation of primary air, Instructions for the installer – Smeg SE97CXG User Manual

Page 11: Referred to distance “ x ” in mm

background image

Instructions for the installer

30

5.3 Regulation for natural gas

The hob has been inspected for G20 (2H) natural gas at a pressure of
20 mbar. To allow the unit to work with this type of gas, perform the same
operations described in paragraph “5.2 Regulation for LPG”, but choose
the nozzles and regulate the primary air for natural gas, as shown in the
following table and in paragraph "5.4 Regulation of primary air”. After the
regulations have been carried out, restore the seals with sealing wax or
equivalent material.


Burner

Rated

heating

capacity

(kW)

Natural gas – G20 20 mbar

Nozzle diameter

1/100 mm

Reduced flowrate

(W)

Auxiliary (1)

1.05

73

380

Semi-rapid (2)

1.65

92

380

Rapid (3)

3.1

126

750

internal (5)

1.05

73

380

Double crown

external (5)

3.9

132

1200


5.4 Regulation of primary air

Referred to distance “X” in mm.

To identify the burners on your hob, refer to the drawings in point “6.3
Arrangement of burners on hob “


BURNER

G20

20 mbar

G30/G31

28/37 mbar

Auxiliary (1)

1.5

2.0

Semi-rapid (2)

2.0

2.0

Rapid (3)

2.5

9.0

internal (5)

4.5

6.0

Double crown

external (5)

3.0

10.0

This manual is related to the following products: