beautypg.com

Sears 28.71234 User Manual

Page 20

background image

18

TROUBLEShOOTING

18.

PROBLEM

POSSIBLE CAUSE

SOLUTION/REASONS

No reading on the am-

meter.

Clamps are not making a

good connection.

2-amp charge rate is be-

ing used.

Check for poor connec-

tions to battery and frame.

Make sure connecting

points are clean.
Ammeter may show no

activity at the 2-amp

charge rate.

Short start cycle when

cranking engine.

Drawing more than 250

amps for a period of 3

seconds or less.

Failure to wait for 4

minutes (240 seconds)

between cranks.

Crank time varies with the

amount of current drawn.

If cranking draws more

than 250 amps, crank

time may be less than 3

seconds.
Wait 4 minutes before

next crank.

METER reading stays

high.

Battery severely dis-

charged.

Wrong battery voltage.

Continue charging battery

for two more hours. If

problem continues, call

Sears Service Center.
Continue charging battery.

Ammeter reads less than

selected charge rate when

charging a discharged

battery.

Extension cord too long or

wire gauge too small.
Weak cell or sulfated plate

in battery.

Battery is only partially

discharged.

Use shorter or heavier

gauge extension cord.
Sulfated battery will

eventually take a normal

charge if left connected. If

the battery will not take a

charge, have it tested by a

Sears technician.
Continue charging battery.

Charger makes a loud

buzz or hum.

Transformer laminations

vibrate (buzz).
Shorted diode (hum).

Continue charging. Buzz

is not abnormal.
Have charger tested by

Sears technician.

If the above solutions do not eliminate the problem

call toll-free from anywhere in the U.S.A.

1-800-SEARS-64

(1-800-732-7764)

7 AM to 4:30 PM Central Time Monday through Friday