2-11

2. Preparation

CAST-AU4/B2521E

Output Circuit

Add the diodes as shown when relay coils are connected as the load.

Be careful that the thermistor operates to shut down the +24 V power supply when 24 V

output is used and the current of 1 A or more flows. Modify the external circuit to reduce
the current capacity to 1 A or less. Thermistor shuts down the +24 V power supply and
returns when the main power is turned on again.
(The maximum current capacity of internal power supply is 1 A.)

Be careful that current capacity is maximum 0.1 A per one output point.

Be sure to use a shielded cable for I/O connection. The maximum length of a shielded

cable is 1.0 m. Use the core conductor of the shielded cable.

NOTE

24V

0V

Note1) 24V

0V

0V IN

24V IN

L 1

L 2

L 22

COM1

0V

SO1
(EMC-OUT)

SO3
(BARRIER)
SO4
(DRIVE)

SO2
(ERROR)

SO8

(

Reservation

)

output

X1

X2

X30

TLP127

20

54

21

68

18

52

19

53

User side

Controller side

Thermistor (1A)

USER I/O power supply source selector slide switch
Up position: Externally supplied 24V
Down position: Internal 24V (default setting)

User external power supply connector
PC board side: MC1.5/2-G-3.81
(Phoenix Contact Inc.)

I/O connector
PC board side PCR-E68LMDA
(Honda communication)

Relay coil voltage
(DC 24V)

Reservation

output

Maximum

0.1A

Direction of

current

Diode

Note1) When USER I/O power supply
source selector slide switch
is set to 24V.

S1