Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003

Sun Proprietary/Confidential: Internal Use Only

TABLE A-1

SRN Reference

SRN

Description

Corrective Action

1xxxx

The SCSI

Request Sense

command has

reported the condition of the disk drive, where
xxxx is the Unit Error Code in Sense Data bytes
20 to 21.

If too many check conditions are returned,
check the link status.

70000

The SAN configuration has changed.

No action is needed.

70001

The rebuild process has started.

No action is needed.

70002

The rebuild completed without error.

No action is needed.

70003

The drive copying information cannot be read
from the primary drive.

If a spare drive is available, use it to
replace the failed drive. If no spare is
available, replace the failed drive with a
new drive.

70004

If the initiator is master, then its follower has
detected a write error on a member within a
mirror drive.

If a spare drive is available, use it to
replace the failed drive. If no spare is
available, replace the failed drive with a
new drive.

70005

If the initiator is master, then it has detected a
write error on a member within a mirror drive.

If a spare drive is available, use it to
replace the failed drive. If no spare is
available, replace the failed drive with a
new drive.

70006

Communication between the virtualization
engines has failed.

Update the firmware.

70007

The primary drive cannot write to the drive
being built.

If a spare drive is available, use it to
replace the failed drive. If no spare is
available, replace the failed drive with a
new drive.

70008

If the initiator is master, then its slave has
detected a read error on a member within a
mirror drive.

If a spare drive is available, use it to
replace the failed drive. If no spare is
available, replace the failed drive with a
new drive.

70009

If the initiator is master, then it has detected a
read error on a member within a mirror drive.

If a spare drive is available, use it to
replace the failed drive. If no spare is
available, replace the failed drive with a
new drive.

70010

The CleanUp configuration table is completed.

No action is needed.

70020

The SAN physical configuration has changed.

If the change was unintentional, check the
condition of the drives.