Troubleshooting Using Microsoft
Windows 2000
General Notes
■
Use the Manufacturer’s HBA Utilities to monitor and diagnose the HBAs. The
examples in this chapter use Qlogic’s SANblade Manager utility.
■
The Storage Automated Diagnostic Environment running on the Storage Service
Processor is not able to monitor the host-to-switch link.
■
The Storage Automated Diagnostic Environment running the Storage Service
Processor is not able to execute
switchtest
(1M) on switch ports with Microsoft
Windows 2000 HBAs currently attached as F ports.
■
The FRUs in the host-to-switch link can be isolated using the HBA utilities on the
host and Storage Automated Diagnostic Environment’s
switchtest
on the
Storage Service Processor, in conjunction with loopback connector plugs.
■
Install the Sun StorEdge T3+ array Failover Driver software before connecting the
host to the switches.