Check the status of the slicd daemon, Check the power on the virtualization engine, Replace the virtualization engine, if necessary – Sun Microsystems 6900 User Manual
Page 154: Sun proprietary/confidential: internal use only

134
Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
oob.slicd
Comm_
Lost
Down
The virtualization engine
failed to execute
slicd
command.
1. Check the status of the slicd
daemon.
2. Check the power on the
virtualization engine.
3. Make sure the virtualization
engine is booted correctly.
4. Verify that the TCP/IP
settings on the virtualization
engine are correct.
5. Check the T3 message log for
failover conditions in the Sun
StorEdge T3+ array.
6. Replace the virtualization
engine, if necessary.
oob.
command
Comm_
Lost
Down
Invalid command or
slicd
daemon problem.
1. Check the status of the slicd
daemon.
2. Check the power on the
virtualization engine.
3. Make sure the virtualization
engine is booted correctly.
4. Verify that the TCP/IP
settings on the virtualization
engine are correct.
5. Check the T3 message log for
failover conditions in the Sun
StorEdge T3+ array.
6. Replace the virtualization
engine, if necessary.
TABLE 9-5
Storage Automated Diagnostic Environment Event Grid for Virtualization Engine (Continued)
Component
EventType
Severity
Information
Required
Action