beautypg.com

Diagnosing a creatediskpools(1m) failure, Diagnosing a, Diagnosing a creatediskpools (1m) failure – Sun Microsystems 6900 User Manual

Page 149

background image

Chapter 9

Troubleshooting Virtualization Engine Devices

129

Sun Proprietary/Confidential: Internal Use Only

Diagnosing a

creatediskpools

(1M)

Failure

When modifying the Sun StorEdge T3+ array configuration on a Sun StorEdge 6900
series, the system should automatically create disk pools. If the virtualization engine
cannot find two paths to all Sun StorEdge T3+ array LUNs, however, the multipath
drives cannot be created. If this happens, the following procedure can help
troubleshoot the problem:

1. Inspect the

SUNWsecfg

log file (

/var/adm/log/SEcfglog

) to see if any errors are

indicated.

In the following example,

creatediskpools

(1M) for

t3b0

indicates a missing Sun

StorEdge T3+ array path.

Thu May 30 17:35:19 MDT 2002 creatediskpools: t3b0 ENTER: /opt/SUNWsecfg/

bin/creatediskpools -n t3b0.

Thu May 30 17:35:19 MDT 2002 checkslicd: v1 ENTER /opt/SUNWsecfg/bin/

checkslicd -n v1.

Thu May 30 17:35:21 MDT 2002 checkslicd: v1 EXIT.

There are no eligible drives to create MultiPath drive automatically.

Thu May 30 17:35:32 MDT 2002 creatediskpools: ERROR: No mpdrives found on

virtualization engine pair v1.

Thu May 30 17:35:32 MDT 2002 creatediskpools: INFO verify all T3+ array

LUNS have 2 paths to the virtualization engine pair, then re-run

creatediskpools.

Thu May 30 17:35:32 MDT 2002 creatediskpools: Failed to create at least

one disk pool.

Thu May 30 17:35:33 MDT 2002 creatediskpools: t3b0 EXIT.

This manual is related to the following products: