Re-enable the controller if possible (enable u), Sun proprietary/confidential: internal use only – Sun Microsystems 6900 User Manual

Page 123

background image

Chapter 8

Troubleshooting the Sun StorEdge T3+ Array Devices

103

Sun Proprietary/Confidential: Internal Use Only

power

State
Change+

The status of the PCU
has changed from ready-
disable to ready-enable.

controller

State
Change+

disk

State
Change+

interface.
loopcard

State
Change+

volume

State
Change+

power

State
Change+

The Sun StorEdge T3+
array has reported that a
LUN has changed state.

controller

State
Change-

Red

Y

The Sun StorEdge T3+
array has reported that a
power cooling unit has
been disabled.

1. Open a Telnet session

to the affected Sun
StorEdge T3+ array.

2. Verify the controller

state with

fru_stat

and

sys_stat

.

3. Re-enable the

controller if possible
(

enable u

)

4. Run

logger -

dmprstlog

from a

serial port session on
the affected controller.
The output from
logger will only go
the the syslog facility.
Review the syslog on
the master controller
to determine the cause
of failure.

5. Replace the controller

as indicated by the
NVRAM failure code.

TABLE 8-1

Storage Automated Diagnostic Environment Event Grid for the Sun StorEdge T3+ Array

Component

Event

T

ype

Se

verity

Action

Description

Action