Verify the correct fc switch configuration, Sun proprietary/confidential: internal use only – Sun Microsystems 6900 User Manual
Page 104

84
Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
port
State
Change+
“port.1 in
SWITCH
diag185
(
ip=
xxx.20.67.185
) is now
Available (status-state
changed from offline to
online)”
The port on the switch is
now available.
port
State
Change-
Red
Y
A port on switch2 has
logged out of the Fabric
connection and has gone
offline.
1. Verify cables, GBICs, and
connections along the FC
path.
2. Check the Storage
Automated Diagnostic
Environment SAN
Topology GUI to identify
failing segment of the
data path.
3. Verify the correct FC
switch configuration.
enclosure
Statistics
“Statistics about
switch
d2-swb1
(ipxxx.0.0.41)
10002000007a609”
TABLE 7-2
Storage Automated Diagnostic Environment Event Grid for 2 GBit Switches (Continued)
Component
EventT
ype
Se
verity
Action
Description
Note:
T
e
xt
within
quotation
marks
(“
“)
is
e
xactl
y
as
it
appear
s
o
n
the
Event
Grid.
Action
Required