Sony DVW-2000P User Manual
Page 133
Chapter 12
Setup Menus
Chapter 12
Setup Menus
12-19
Menu items in the range 600 to 699, relating to the time code generator (Continued)
Item number
656
657
658
659
660
Item name
MATERIAL NO.
ESSENCE MARK TAPE
OUTPUT
SHOT MARK ESSENCE
MARK CONVERT
AED ESSENCE MARK
CONVERT
ESSENCE MARK SD
VANC LINE
Settings
Select whether to inherit the UMID in the input signal when recording a UMID.
INPUT : Inherit the UMID in the input signal, if it is present.
• Even when INPUT is selected, a new UMID is generated if the input signal
does not contain UMID data (the same behavior as when NEW is selected).
• When recording with inherited data, the Instance Number is newly generated
according to menu item 654, changing to a value that indicates that “this is a
copy”.
• When the UMID in the input signal is a Basic UMID, a Basic UMID is
recorded, even if menu item 655 is set to EXTENDED.
• When the UMID in the input signal is an Extended UMID, the recorded UMID
follows the setting of menu item 655.
NEW: Generate a new UMID, regardless of whether or not the input signal
contains a UMID.
• The Basic section does not change during recording.
• An Instance Number indicating that “this is the original” is generated.
• The Source Pack Date/Time (when) changes with each frame.
• The Source Pack Spatial Co-ordinates (where) are not recorded.
• The Source Pack Stored Ownership (who) can be set.
(See the section “To
set Stored Ownership” (page 8-2)).
Select whether or not to output essence marks recorded on the tape during
playback.
off : Do not output.
on: Output.
Note
When menu item 901 VIDEO OUTPUT DATA is set to “8 bit”, nothing of UMID is
output regardless of the setting of this menu item.
Select whether or not to convert into essence marks and output shot marks
recorded in the LTC track which are detected during playback.
off : Do not output.
SHOTM: Output.
Depending on the type of the detected shot marks, the output essence marks are
“_RecStart”, “_ShotMark1”, or “_ShotMark2”.
Notes
• Of the shot marks, post marks are not converted to essence marks.
• Shot mark detection timing depends on playback conditions.
• When menu item 901 VIDEO OUTPUT DATA is set to “8 bit”, nothing of UMID is
output regardless of the setting of this menu item.
Select whether or not to convert into essence marks and output events detected
during playback by the AED (Auto Event Detector).
off : Do not output.
on: Output.
Note
When menu item 901 VIDEO OUTPUT DATA is set to “8 bit”, nothing of UMID is
output regardless of the setting of this menu item.
Specify the VANC line into which to insert essence marks during video recording
and playback.
12H, 13H, 15H, 16H, 17H , 18H, 19H (DVW-M2000/2000)
9H, 10H, 12H, 13H, 14H, 15H, 16H, 17H , 18H (DVW-M2000P/2000P)
Notes
• The output VANC line during playback follows the setting for recording.
• The VANC line for SDI signal E-E output of essence marks contained in the
input SDI signal follows the input.
(Continued)