AIRLOCKS

When a pump airlocks, it runs but does not move any water. An airlock
will cause the pump to overheat and fail. This pump has an anti-airlock
hole in the bottom of the pump body. If you suspect an airlock, unplug
the pump, clean out the anti-airlock hole with a paper clip or piece of
wire, and restart the pump.
IMPORTANT: This hole allows the pump to start priming within
15 seconds in as little as 1/2" of water. NEVER restart pump in less
than 1/2" of water. Leakage from the anti-airlock hole is normal.

* Lake Chemical Co., Chicago, Illinois

Key

Part Description

Qty.

Part No.

1

Screen

1

PS8-5P

2

Shield

1

PS70-3P

3

Impeller

1

PS5-25P

4

Motor

1

**

5

Power Cord

1

PS117-54-TSU

Garden Hose Adapter

1

FT0013-43

Model 2325

TROUBLESHOOTING

** If motor fails, replace entire pump.
• Not Illustrated.

Assemble screen and shield as shown.

3

2

4

5

1

Anti-Airlock
Hole

5125 0905

SYMPTOM

POSSIBLE CAUSE(S)

CORRECTIVE ACTION

Pump won’t

Blown fuse

If blown, replace with fuse of proper size

start or run

Low line voltage

If voltage under recommended minimum, check size of wiring
from main switch on property. If OK, contact power company.

Defective motor

Replace pump

Impeller

If impeller won’t turn, remove screen. Locate source of binding

Pump operates but

Low line voltage

Use only 14 gauge or larger extension cords. Use short extension cords

delivers little or

when necessary

no water

Something caught in impeller

Clean out impeller

Small diameter garden hose

Use larger diameter garden hose or 1" flexible pipe. Eliminate any

or long discharge line

excess hose. Short hoses work best

Check valve installed without

Drill a 1/16" - 1/8" (1.6 - 3.2 mm) dia. hole between pump

vent hole

discharge & check valve

Air lock

Turn off pump for a few seconds, clean out anti-airlock hole and restart pump

Coils or bends in hose

Straighten hose

3rd

Anti-Airlock
Hole

5124 0905

Tighten 1st

Orient Part Number with
Anti-Airlock Hole as shown

2nd

3

2

4

5

1

Anti-Airlock
Hole

5125 0905