Adjusting the flange focal length automatically, Adjusting the flange focal length manually – Sony HVR-Z7E/Z7P User Manual
Page 11
11
Ge
tt
in
g
S
ta
rte
d
Adjusting the flange focal length
automatically
1
Set the
ND
filter B to 1 to adjust
brightness so that the proper video light
level is obtained.
2
Place the flange focal length adjustment
test chart A about 2-3 meters (7-10
feet) away. Zoom in and set your
camcorder to locate the center of the
chart in the center of the screen.
3
Set the ZOOM switch F to SERVO.
4
Select [AUTO ADJUST] in [FLANGE
BACK] of the
(CAMERA SET)
menu
.
5
Select [YES] with the SEL/PUSH
EXEC dial E.
The flange focal length adjustment starts
and [EXECUTING] appears on the screen.
When the adjustment is completed,
[Completed.] appears on the screen.
If the adjustment fails, [Could not adjust.]
appears on the screen. Try the adjustment
again.
Adjusting the flange focal length
manually
1
Perform steps 1 and 2 of “Adjusting
the flange focal length automatically.”
2
Set the ZOOM switch F to MANUAL.
3
Select [MANU ADJUST] in [FLANGE
BACK] of the
(CAMERA SET)
menu.
4
Select [YES] with the SEL/PUSH
EXEC dial E.
5
Turn the zoom ring D to the telephoto
position.
6
Turn the focus ring C until the subject
comes in focus, then press the SEL/
PUSH EXEC dial E.
7
Turn the zoom ring D to the wide angle
position.
8
Turn the focus ring C until the subject
comes in focus, then press the SEL/
PUSH EXEC dial E.
When the adjustment is completed,
[Completed.] appears on the screen.
If the adjustment fails, [Could not adjust.]
appears on the screen. Try the adjustment
again.
z
Tips
• You can check the focusing easily if you do the
following before adjusting the focal length.
– Set [PEAKING] in the
(DISPLAY
SET) menu to [ON] (p. 79).
– Press the ASSIGN button to which
[EXP.FOCUS] is assigned (L2 button by
default) (p. 43).
ZOOM
SERVO
MANUAL
Continued
,