Conversion Kit

6

4)

To adjust the cooktop for LP gas or to return to Natural Gas use, refer to the tables here below.

Natural gas

LP

Qt

Injector

Qr

Qt

Injector

Qr

by-pass

BTU

Ø mm

BTU

BTU

Ø mm

BTU

mm

Front Right

3400

0.90

1200

Front Right

3400

0.54

1200

0.32

Front Left

3400

0.90

1200

Front Left

3400

0.54

1200

0.32

Central

13000

1.75

4000

Central

13000

1.02

4000

0.63

Rear Right

6200

1.20

1500

Rear Right

6200

0.72

1500

0.38

Rear Left

6200

1.20

1500

Front Left

6200

0.72

1500

0.38

NOTE: Save the orifices removed from the appliance for future use.

5)

After carrying out the above adjustments, remount in reverse order to the instructions given in point “3”.

Caution: refit all flame caps in the same points from which they were removed. In fact, it is not possible to
change the flame cap positions. After refitting them, ensure that they are perfectly in place and that there
is no clearance between the cooktop and the flame caps.

WARNING

FIRE HAZARD

- Use a soapy solution to check for proper tightness.

- Never test for gas leaks with a match or other flames.

- Failure to follow this instruction can result in death or fire