Conversion Kit
6
4)
To adjust the cooktop for LP gas or to return to Natural Gas use, refer to the tables here below.
Natural gas
LP
Qt
Injector
Qr
Qt
Injector
Qr
by-pass
BTU
Ø mm
BTU
BTU
Ø mm
BTU
mm
Front Right
3400
0.90
1200
Front Right
3400
0.54
1200
0.32
Front Left
3400
0.90
1200
Front Left
3400
0.54
1200
0.32
Central
13000
1.75
4000
Central
13000
1.02
4000
0.63
Rear Right
6200
1.20
1500
Rear Right
6200
0.72
1500
0.38
Rear Left
6200
1.20
1500
Front Left
6200
0.72
1500
0.38
NOTE: Save the orifices removed from the appliance for future use.
5)
After carrying out the above adjustments, remount in reverse order to the instructions given in point “3”.
Caution: refit all flame caps in the same points from which they were removed. In fact, it is not possible to
change the flame cap positions. After refitting them, ensure that they are perfectly in place and that there
is no clearance between the cooktop and the flame caps.
WARNING
FIRE HAZARD
- Use a soapy solution to check for proper tightness.
- Never test for gas leaks with a match or other flames.