background image

Danaher Motion Superior Electric

SS2000MD4

17

400030-043 Rev G

4.7.4 Timing Requirements

PULSE

Max. Frequency....... 20 kHz
Max. Rise and
Fall Times................ 1 microsecond
Min. Pulse
Width ....................... 25 microseconds

Other Signals

Response Time ....... 25 microseconds

4.5 - 6.0 VDC, 16 mA PER SIGNAL

OPTO IN

PULSE

DRIVE

CONTROL SIGNAL

TTL

7406

5V

OPTO IN

PULSE

DRIVE

SWITCH

OPTO 5V GND

OPTO IN

PULSE

DRIVE

560 ohms

1/4 watt

12 VDC, 16 mA PER SIGNAL

CONTROL SIGNAL

CONTROL LOGIC COMMON

4.5 - 6.0 VDC, 16 mA PER SIGNAL

OPTO IN

PULSE

DRIVE

CONTROL SIGNAL

CONTROL LOGIC COMMON

Figure 4.2 Suggested Methods For Control Interface

4.8 I

NDICATOR

L

IGHTS

"FAULT" LED, Red

Lights to indicate over current condition. This condition is caused by motor wiring errors or a
ground fault.

Recovery from over current condition requires removing and then reapplying the power.