3.3.1 Motor Connections

All motor connections are made via the 6-terminal strip (J1). Terminal assignments are
given below. Motor connections are shown in Figure 3.3

.

J1 Pin Assignment
1

M1 (Phase A+)

2

M3 (Phase A-)

3

M4 (Phase B+)

4

M5 (Phase B-)

Motor phase A is M1 and M3 and motor phase B is M4 and M5. The
motor frame must be grounded.

Cabling from the drive to the motor should be done with a shielded, twisted pair cable.
As a guideline, the wires for each motor phase should be twisted about six times per foot.

Danaher Motion offers the following motor cable configurations. These cables have
unterminated leads on both ends.

Length

Part Number

10 ft (3 m)

216022-031

25 ft (7.6 m)

216022-032

50 ft (15.2 m) 216022-033
75 ft (22.8 m) 216022-034

Figure 3.3 shows the possible motor wiring configurations.