beautypg.com

Specifications – State Models: 305 User Manual

Page 3

background image

305, 505, 705 Indoor Manual

3

Specifications

Specifications are subject to change without prior notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.

* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

** for commercial and hydronic applications requiring higher temperatures

Model

305

505

705

Minimum Gas Consumption Btu/h

15,000

19,000

Maximum Gas Consumption Btu/h

180,000

199,000 Natural Gas

190,000 Propane Gas

237,000

Hot water capacity (Min - Max) *

0.6 - 7.5 GPM

(2.3 - 28.4 L/min)

0.6 - 9.4 GPM

(2.3 - 35.5 L/min)

0.6 - 9.8 GPM

(2.3 - 37 L/min)

Hot water capacity (45°F rise)

6.6 GPM (25.0 L/min)

7.4 GPM (28.0 L/min)

Natural Gas

7.1 GPM (26.9 L/min)

Propane Gas

8.8 GPM (33.5 L/min)

Default Temperature Setting (no controller)

120º F (49º C)

Temperature Controller Default Setting

104º F (40º C)

Maximum Temp Setting (Commercial) **

160º F (71º C)

185º F (85º C)

Maximum Temp Setting (Residential)

Selectable at 120º F (49º C) or at 140º F (60º C)

140º F (60º C)

Minimum Temperature Setting

98º F (37º C)

Weight

50 lb (23 kg)

55 lb (25 kg)

Efficiency Rating

84%

Noise level

49 dB

Electrical Consumption

Normal

65 W

79 W

99 W

Standby

Anti-frost Protection

100 W

116 W

By-Pass Control

Fixed

Electronic

Minimum Gas Supply
Pressure

Natural Gas

5.0 inch W.C.

Propane

8.0 inch W.C.

Maximum Gas Supply
Pressure

Natural Gas

10.5 inch W.C.

Propane

13.5 inch W.C.

Type of Appliance

Direct Vent, Temperature controlled continuous flow gas hot water system.

Operation

With or without temperature controls, mounted in kitchen, bathroom, etc.

Approved Gas Type

Natural Gas or Propane - Ensure unit matches gas type it's being installed on.

Connections

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT

Ignition System

Direct Electronic Ignition

Electric Connections

Appliance: AC 120 Volts, 60Hz. Temperature Control: DC 12 Volts (Digital)

Water Temperature Control

Simulation Feedforward and Feedback.

Water Supply Pressure

Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum performance)

Maximum Water Supply Pressure

150 PSI

Temperature Control Cable

Non-Polarized Two Core Cable (Minimum 22 AWG)

Energy Star Qualified

Yes

Yes

No

2 W

This manual is related to the following products: