Ipmi configuration (x8sia-f only) – SUPER MICRO Computer SUPERO X8SIA-F User Manual
Page 94
4-18
X8SIA/X8SIA-F
IPMI Configuration (X8SIA-F Only)
Intelligent Platform Management Interface (IPMI) is a set of common interfaces that
IT administrators can use to monitor system health and to manage the system as a
whole. For more information on the IPMI specifications, please visit Intel's website
at www.intel.com.
IPMI Firmware Revision
This item displays the current IPMI firmware revision.
Status of BMC
Baseboard Management Controller (BMC) manages the interface between system
management software and platform hardware. This is an informational feature which
returns the status code of the BMC micro controller.
View BMC System Event Log
This feature is used to view any BMC events. It shows the total number of entries
and will allow the viewing of each event by scrolling down on an Entry Number
and pressing Enter.
Clear BMC System Event Log
This feature is used to clear the System Event Log. Caution: Any cleared information
is unrecoverable. Make absolutely sure you no longer need any data stored in the
log before clearing the BMC Event Log.
Set LAN Configuration
Set this feature to configure the IPMI LAN adapter with a network address.
Channel Number - Enter the channel number for the SET LAN Config com-
mand. This is initially set to
[1]. Press <+> or <-> on your keyboard to change
the Channel Number.
Channel Number Status - This feature returns the channel status for the
Channel Number selected above: "Channel Number is OK" or "Wrong Channel
Number".
IP Address Source - This feature selects whether the IP address, Subnet
Mask and Gateway Address are automatically assigned by the network's DHCP
server (Dynamic Host and Configuration Protocol) or manually entered by the
user (Static). If Static is selected, the IP Address, Subnet Mask and Gateway
Address must be manually entered below. If DHCP is selected, the next three
items will be configured automatically and will be grayed out. The options are
Static and
DHCP.