61

Error Message

on Display

Printed

Message

Description

Action

File System
Error Can’t Open
File

There was an internal
error while trying to
access flash for audit
trail

Check that Flash is
installed and not full.

Flash Full Purge
and Format

This error message
indicates that the
printer’s flash memory
is full. The audit trail
cannot accept more
jobs until more space is
available in flash.

Press Go then purge the
audit trail. Then either
defragment or format flash
memory (Utilities Menu).

Integer string
incorrect length

Integer string
incorrect
length

A parameter in a
command was not the
correct length.

Check the Command
(&%STP, STS) for
syntax/numbering errors.

Invalid
AES/DES key

Invalid hex digit or
length of decryption
key

Check the syntax of
SETAESKEY or
SETDESKEY command.

Invalid Convert
to Escape
Character

Invalid
Convert to
Escape
Character

An error was detected
in the User
Programmable Escape
Character Selection
Command. The
software tried to
specify a NULL or an
ampersand as the first
Escape Character.

Check the Command
(&%STY...) for errors.

Macro Definition
Error

Invalid
decode mode
specified

The Load Flash
Resource Command
contained an invalid
character specifying
the format of the file.
Must be either a D or
S.

Check the Command
(&%STL...) for syntax
errors.

Macro Definition
Error

Macro ID
greater than
32767 limit.

The resource number
in the Load Flash
Resource Command
(&%STL...) was over
the 32767 limit.

Check the Load Flash
Resource Command for
syntax/numbering errors.

Macro Definition
Error

Macro size
exceeds
available
space

Flash resource file size
specified in the Load
Flash Resource
Command is too large
for the available space
remaining in the flash
module.

Format flash memory to
remove all existing
resources or upgrade
flash memory to a larger
module.