beautypg.com

Source Technologies MICR ST9650 User Manual

Page 36

background image

Source Technologies, LLC ST9650 Secure MICR Printer User’s Guide

36

Caution: Errors made in sending the new password command could lead to
setting it to an unknown value. If the Password is unknown the printer must be
returned to Source Technologies to be reset to PASSWORD.

Activate/Set Front Panel Combination Lock

&%STSxxxxxxxx$ (optional)

&%STS

Lead in sequence

xxxxxxxx

Eight digit sequence, valid characters 0-9

$

Command terminator


Sets and activates the front panel MICR combination lock. If this feature is activated,
MICR mode cannot be entered until the front panel combination is entered correctly. All
MICR features will be inaccessible until this combination is entered. Sending an &%STS
command and eight zeros deactivates the security lock.

Caution: If the front panel combination is set and then forgotten, the printer must
be returned to Source Technologies for the combination to be deactivated.

Print MICR E-13B Font

&%SMDddd...ddd$

&%SMD

Lead in sequence

ddd...ddd

Data to be printed in E-13B MICR font

$

Command terminator


Prints the specified data in the E-13B MICR font which is used in the United States,
Canada and Mexico. The correct spacing begins at the cursor position modified by the
MICRpoint adjustment setting at the start of the command. After the terminator is sent,
the printer is returned to its default font. After each Print E-13B command, the MICR
count is decremented by one. Upon receiving this command the printer will verify that a
MICR toner cartridge is installed and set the copies parameter to 1. See Appendix A for
MICR E-13B font character mapping.